3M · Air purifier
3M Taiwan 智淨 / 倍淨 air purifiers — official filter table (U100 / U200 / U300)
Last verified: 2026-11-19(Asia/Taipei) · TW
3M Taiwan’s official selection table maps FA-B200DC, FA-E180, FA-U150, FA-U120, and FA-U90 to specific U-series genuine filters and optional odor-control filters.
Official compatible models
| Model | Notes |
|---|---|
| FA-B200DC | Official table: standard filter U100-F; optional odor-control filter U100-ORF. The FA-B200DC series page also notes that this filter size is additionally specified for FA-B90DC and FA-U90. |
| FA-E180 | Official table: U300-F standard; U300-ORF optional odor-control. |
| FA-U150 | Official table: U200-F standard; U200-ORF optional odor-control. |
| FA-U120 | Official table: U200-F standard; U200-ORF optional odor-control. |
| FA-U90 | Official table: U100-F standard; U100-ORF optional odor-control. |
| FA-B90DC | Not a row in the main table, but the official FA-B200DC series page states the U100-size filter also applies to FA-B90DC and FA-U90. |
Genuine filter part numbers
| Part number | Official name | Replacement interval (manufacturer) | Notes |
|---|---|---|---|
| U100-F | 3M 淨呼吸 long-life electrostatic filter U100-F (standard for FA-B200DC and FA-U90; also noted for FA-B90DC) | 3M’s official FA-B200DC series page states that the new long-life electrostatic filter “最長可使用高達 1.4年*” (can be used for up to 1.4 years), with an asterisk. Treat this as a manufacturer maximum under the conditions of that footnote, not a fixed calendar interval for every home. Follow the unit’s indicator and the current 3M page. | Listed as the included/standard replacement filter (“隨機替換濾網”) for FA-B200DC and FA-U90 on the official table. |
| U100-ORF | 3M odor-control electrostatic filter U100-ORF (optional, same size group as U100-F) | The official table marks this as an optional odor-control filter. The “up to 1.4 years*” wording on the series page refers to the new long-life electrostatic filter generally; check the specific U100-ORF product page for any different interval. | Official optional filter for FA-B200DC and FA-U90 (and noted with the U100 size group for FA-B90DC). |
| U200-F | 3M standard filter U200-F for FA-U150 and FA-U120 | No separate month count is printed in the official selection table. See the 1.4-year* maximum stated for the new long-life electrostatic filter on the related official series page, and confirm on the specific filter’s product listing. | Official standard replacement (“隨機替換濾網”) for FA-U150 and FA-U120. |
| U200-ORF | 3M optional odor-control filter U200-ORF for FA-U150 and FA-U120 | Not given as a separate figure on the official selection table; confirm on the U200-ORF product page. | Official optional odor-control filter for FA-U150 and FA-U120. |
| U300-F | 3M standard filter U300-F for FA-E180 | No separate month count is printed in the official selection table; see the series-page 1.4-year* wording and the specific product listing. | Official standard replacement for FA-E180. |
| U300-ORF | 3M optional odor-control filter U300-ORF for FA-E180 | Not given as a separate figure on the official selection table; confirm on the U300-ORF product page. | Official optional odor-control filter for FA-E180. |
Third-party alternatives
None listed. We only publish a third-party alternative when we have a source we can cite for that exact substitution.
How to confirm this is your machine
The model (FA-B200DC, FA-E180, FA-U150, FA-U120, FA-U90, or FA-B90DC) is on the unit and in 3M’s table. Other 3M Taiwan families (for example FA-V300 / V300-NWF, FA-S500 / S500-CF) have their own official product names and are not merged into this table.
Replacement notes (from official instructions)
Follow the user manual for your exact 3M model for cover removal and any reset procedure. This page only records the official mapping and the interval wording published on the 3M Taiwan series pages we checked.
Limits of this page
The 1.4-year figure is published with an asterisk on 3M’s official series page. We could not capture the full footnote text from that page extract, so we do not convert it into a bare “replace every 16 months” rule. Other 3M Filtrete models sold in Taiwan are omitted until we cite their official rows.
- 3M Taiwan official 智淨/倍淨 selection guide (model-to-filter table) — 3M Taiwan. Accessed 2026-11-19.